RF8220-3D-400 3D Laser Galvo Scanner for RF CO2 Laser
The RF8220-3D-400 dynamic focus scanning system is suitable for a wide range of laser marking, cutting, laser micromachining, 3D applications, laser rapid prototyping, etc. , cloth and other non-metallic materials for processing. Good running stability, high positioning accuracy, fast marking speed, strong anti-interference ability, high precision marking line, no deformation, uniform power, no distortion of pattern in the dynamic marking process, comprehensive performance index reached the international leading level in the field.
The advantages are as following:
■ Adopt photoelectric sensing technology and PDM control method, combined with the R&D technology of the Ministry of Aerospace and the production technology of vehicle-level.
■ Adopt advanced optical design scheme, small light loss, small size, high positioning accuracy, fast marking speed, strong anti-interference ability, etc. It is suitable for laser fine processing such as plane, complex curved surface and deep engraving.
■ Adopt MM3D software system, support a variety of file formats and import vector graphics, bitmaps and text barcodes, easy to understand, easy to operate, easy to use.
■ The maximum size of marking is 400×400mm, and any size from 200×200mm to 400×400mm can be customized according to requirements.
■ Precise load design for 20mm spot lens, high motor assembly precision, reasonable structure, small static friction coefficient and zero offset, to ensure good dynamic characteristics of the system.
■ The driver has the function of position and speed advance detection, which greatly improves the dynamic response performance and scanning speed of the whole system.
■ Solve common problems such as galvanometer motor temperature drift, signal interference and zero drift.
RF8220-3D-400 Technical Parameters
Laser Type
10600nm RF CO2 laser source
Field Size
200×200mm~400×400mm
Input Beam Size
3.5mm
X&Y Axes Mirrors Aperture Size
20mm
Speed
Marking Speed
2000mm/s
Writing Speed
124cps
Step Response Time(1% of full scale)
708μs
Step Response Time(10% of full scale)
1320μs
Tracking Error Time
≤374μs
Precision and Error
Linearity
99.9%
Repeatability (RMS)
<8μRad
Gain Error
<5mRad
Zero Offset
<5mRad
Long-term Drift Over 8 Hours
<0.5mRad
Scale Drift
<40PPM/℃
Power and Signal
Input Voltage
±24VDC
Rated Current
4A
Interface Signal
Digital: XY2-100
Machinery Scan Angle
±12.5°
Working Current, Temperature, Dimension
Working Temperature
0℃~45℃
Storage Temperature
-10℃~60℃
Galvanometer Scanner Dimension
400×148×149mm (L×W×H)
Galvanometer Scanner Weight
≈7.8Kg
Water-Cooling System
Water Temperature
25±3℃
Maximum water pressure
<3bar
Water flow
>1L/min
Water pipe specification
Outer diameter φ6mm
Inner diameter φ4mm